Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
SINAMICS G115D distributed drive
482
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
11.3.31
Mounting positions
11.3.31.1
General notes on mounting positions
Only operate the gearbox in the mounting position specified on the rating plate. This ensures
that the correct quantity of lubricant is provided. The symbols are shown for the standard
mounting position.
Note
Gearbox sizes 19 and 29
Gearbox sizes 19 and 29 are lubricated for life. There is no opening to check the oil level.
In mounting positions M2 and M4 the gearboxes are equipped with a breather valve.
C29 has a breather valve in all mounting positions.
Description of the symbols:
Venting
Oil level
Oil drain
A, B Position of insert shaft / solid shaft
*
On opposite side
①
Oil level check not possible for tandem gearbox (main gearbox a)
②
Two-stage gearbox
③
Three-stage gearbox