Operation
6.7 Communication according to PROFIdrive
Converter cabinet units
322
Operating Instructions, 07/2016, A5E03347396A
6.7.3.3
Overview of control words and setpoints
Table 6- 16 Overview of control words and setpoints
Abbreviation
Description
Parameter
Function diagram
STW1
Control word 1 (interface mode
SINAMICS, p2038 = 0)
See table "Control word 1 (interface mode
SINAMICS, p2038 = 0)"
FP2442
STW1
Control word 1 (interface mode VIK-
NAMUR, p2038 = 2)
See table "Control word 1 (interface mode
VIK-NAMUR, p2038 = 2)"
FP2441
STW1_BM
Control word 1, metal industry (interface
mode SINAMICS, p2038 = 0)
See table "Control word 1, metal industry
(interface mode SINAMICS, p2038 = 0)"
FP2425
STW2
Control word 2 (interface mode
SINAMICS, p2038 = 0)
See table "Control word 2 (interface mode
SINAMICS, p2038 = 0)"
FP2444
STW2_BM
Control word 2, metal industry (interface
mode SINAMICS, p2038 = 0)
See table "Control word 2, metal industry
(interface mode SINAMICS, p2038 = 0)"
FP2426
NSOLL_A
Speed setpoint A (16-bit)
p1070
FP3030
NSOLL_B
Speed setpoint B (32-bit)
p1155
FP3080
PCS7_x
PCS7-specific setpoints