Diagnosis/faults and alarms
10.2 Diagnosis
Converter cabinet units
594
Operating Instructions, 07/2016, A5E03347396A
10.2
Diagnosis
Description
This section describes procedures for identifying the causes of problems and the measures
you need to take to rectify them.
Note
Errors or malfunctions
If errors or malfunctions occur in the device, you must carefully check the possible causes
and take the necessary steps to rectify them. If you cannot identify the cause of the problem
or you discover that components are defective, your regional office or sales office should
contact Siemens Service and describe the problem in more detail. Addresses of contact
persons are listed in the preface.
10.2.1
Diagnostics using LEDs
Control Unit (-A10)
Table 10- 1 Description of the LEDs on the CU320-2 DP Control Unit
LED
Color
State
Description
RDY (READY)
---
OFF
The electronic power supply is missing or lies outside the permis-
sible tolerance range.
Green
Continuous light
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
0.5 Hz flashing
light
Commissioning/reset
2 Hz flashing light Writing to the memory card.
Red
2 Hz flashing light General fault
Red/green 0.5 Hz flashing
light
Control Unit is ready for operation.
However, there are no software licenses.
Orange
0.5 Hz flashing
light
Firmware update in progress for the connected DRIVE-CLiQ com-
ponents.
2 Hz flashing light Firmware update of components has been completed. Wait for
POWER ON of the respective component.
Green/
orange or
red/orange
2 Hz flashing light Component detection via LED is activated (p0124[0]).
Note:
Both options depend on the LED status when component recogni-
tion is activated via p0124[0] = 1.