Operation
6.3 Basic information about the drive system
Converter cabinet units
270
Operating Instructions, 07/2016, A5E03347396A
Digital signals, which can be connected freely by means of BICO parameters, are identified
by the prefix BI, BO, CI or CO in their parameter name. These parameters are identified
accordingly in the parameter list or in the function diagrams.
Note
Using STARTER
The STARTER parameterization and commissioning tool is recommended when using BICO
technology.
Binectors, BI: binector input, BO: Binector output
A binector is a digital (binary) signal without a unit which can assume the value 0 or 1.
Binectors are subdivided into binector inputs (signal sink) and binector outputs (signal
source).
Table 6- 3
Binectors
Abbreviation and
symbol
Name
Description
Binector input
(signal sink)
Can be interconnected to a binector output as
source.
The number of the binector output must be en-
tered as a parameter value.
Binector output
(signal source)
Can be used as a source for a binector input.
Connectors, CI: connector input, CO: Connector output
A connector is a digital signal e.g. in 32–bit format. It can be used to emulate words (16 bits),
double words (32 bits) or analog signals. Connectors are subdivided into connector inputs
(signal sink) and connector outputs (signal source).
The options for interconnecting connectors are restricted to ensure that performance is not
adversely affected.
Table 6- 4
Connectors
Abbreviation and
symbol
Name
Description
Connector input
(signal sink)
Can be interconnected to a connector output as
source.
The number of the connector output must be
entered as a parameter value.
Connector output
(signal source)
Can be used as a source for a connector input.