7.6
Technical data
Table 7-1
Technical data of the Hybrid Cabinet Bushing
Technical data
Unit
6SL3555-2DA00-0AA0
DC link voltage
V
DC
510 … 720
Current-carrying capacity of the DC link
(T
ambient
< 40 °C)
A
DC
25
Current-carrying capacity of the elec‐
tronics
A
DC
10
Mounting position/type of construction
Any
Cooling method
Natural convection
Dimensions
(W x H x D; without connectors and
caps)
mm
139 x 139 x 72
Weight
kg
0.85
Degree of protection
IP65
The Hybrid Cabinet Bushing fulfills the same thermal and mechanical specifications as the
S120M.
The derating characteristic of the S120M regarding the installation altitude and the temperature
also apply to the Hybrid Cabinet Bushing.
7.6.1
Characteristics
● If the components are operated at increased ambient temperatures (40 to 55 °C) then the
DC link current must be appropriately reduced.
3H
UP
LV
VL
EO
H
RX
WS
XW
F
XU
UH
QW
$PELHQWWHPSHUDWXUH
>@
>r&@
Figure 7-4
Output current as a function of the ambient temperature
Hybrid Cabinet Bushing
7.6 Technical data
Manual, 06/2019, 6SL3097-5AW00-0BP1
123
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......