Now you can remove the S120M.
NOTICE
Damage to the signal cables when replacing the S120M
Signal cables can be damaged when the S120M is disassembled.
● When withdrawing the S120M, ensure that you do not damage any signal cables.
Installation steps
To install the AM600, perform the removal steps in the reverse order.
NOTICE
Equipment damage due to unsuitable tightening torques
Unsuitable tightening torques can cause damage to components.
● Carefully insert the plug connections and ensure that they are secure.
● Attach the hybrid cable using an Allen key and check that the connections are secure.
9.2.4
Replacing a fuse in the Adapter Module 600
Preparatory steps
1. Disconnect the drive line-up.
2. Allow unimpeded access to the Adapter Module 600 (AM600).
3. Check that the cabinet is de-energized.
Service and maintenance
9.2 Replacing components