9.6.4.4
Disconnecting the fiber-optic cables
Tools required
You require a fiber-optic cable cutter (Order No. A5E02615209) to cut the fiber-optic cables to
length.
Procedure
NOTICE
Destruction of the fiber-optic cables
Fiber-optic cables can be destroyed under the following conditions:
● The bending radius is less than 20 mm.
● The fiber-optic cables are subject to strong light.
● The fiber-optic cables are exposed to temperatures of over 80° C.
Handle the fiber-optic cables carefully. Do not bend them with a bending radius of less than
20 mm. Protect the fiber-optic cables from heat and strong light.
①
Knurled nut
②
Fiber-optic cable
Figure 9-6
Releasing a fiber-optic cable
To disconnect the fiber-optic cables, proceed as follows:
1. Carefully unscrew the knurled nut
①
.
2. Pull the fiber-optic cable
②
out.
3. Insert the new fiber-optic cable as far as it will go. If correctly fitted, the white ID ring must be
flash with the opto-transmitter or opto-receiver.
4. Tighten the knurled nut
①
again by hand.
Maintenance
9.6 Repairs
SINAMICS SL150 6SL38655UM427AA02
Operating Instructions Rev.201910281507 EXAMPLE
83