P2887[0...1]
CI: CMP 2
0 - 4294967295
0
U, T
4000H
-
U32
3
Defines inputs of Comparator 2, output is r2888.
Index:
See P2869
Dependency:
P2802[13] assigns the Comparator to the processing sequence.
r2888.0
BO: CMP 2
-
-
-
-
-
U16
3
Displays result bit of Comparator 2. See r2811 for the bit field description.
Dependency:
See P2887
P2889
CO: Fixed setpoint 1 in
[%]
-200.00 - 200.00
0.00
U, T
-
-
Float
3
Fixed percent setting 1.
P2890
CO: Fixed setpoint 2 in
[%]
-200.00 - 200.00
0.00
U, T
-
-
Float
3
Fixed percent setting 2.
P2940
BI: Release wobble
function
0 - 4294967295
0.0
T
-
-
U32
2
Defines the source to release the wobble function.
P2945
Wobble signal frequen-
cy [Hz]
0.001 - 10.000
1.000
T
-
-
Float
2
Sets the frequency of the wobble signal.