3 Configuration
SINAUT MD741-1
30
C79000-G8976-C236-05
The start page is displayed
After the user name and password are entered, the start page of the SINAUT
MD741-1 appears in the Web browser with an overview of the operating state, see
Chapter 3.4.
The start page is not displayed
If after several tries the browser still reports that the page cannot be displayed, try
the following:
●
Check the hardware connection. On a Windows computer, go to the DOS
prompt (Menu
Start, Programs, Accessories, Command Prompt
) and enter the
following command:
ping 192.168.1.1
If a return receipt message for the 4 packets that were sent out does not
appear within the specified time period, check the cable, the connections and
the network card.
●
Make sure that the browser does not use a proxy server. In MS Internet
Explorer (Version 7.0), make these settings as follows: Menu
Tools, Internet
Options
...
, tab
Connections
: Under
LAN Settings
, click on the
Settings...
button,
then in the dialog box
Settings for local network (LAN)
, make sure that under
Proxy Server
the entry
Use proxy server for LAN
is not activated.
●
If other LAN connections are active on the computer, deactivate them for the
duration of the configuration process.
Under the Windows menu
Start, Connect To ..., Show All Connections…
,
under LAN or High-Speed Internet right-click on the connection concerned and
select
Deactivate
in the pop-up menu.
●
Enter the address of the SINAUT MD741-1 with a slash:
https://192.168.1.1/