6 Security functions
SINAUT MD741-1
76
C79000-G8976-C236-05
Is forwarded to IP address
Specify here the IP address in the local network to which the incoming data
packets should be forwarded.
Is forwarded to port
Specify here the port number (e.g.) for the IP address in the local network to which
the incoming data packets should be forwarded.
Log
For each port forwarding rule you can define whether the event should be
●
logged when the rule takes effect - set Log to Yes
●
or not - set Log to No (factory settings)
The log is kept in the firewall log, see Chapter 6.4.
Factory settings
The factory settings for the SINAUT MD741-1 are as follows:
Forwarding Rules
-
Protocol
All
Arrives at port
80
Is forwarded to IP address
127.0.0.1
Is forwarded to port
80
Log
No (switched off)