Technical Appendix
SINUMERIK 801
7-2
Start-Up
rev/min
_always 5
(0.014)
0.0
plus
DOUBLE
36100 POS_LIMIT_MINUS
mm,
deg.
1st software limit switch minus
RESET
_always –100000000 –
–
DOUBLE
36110 POS_LIMIT_PLUS
mm,
deg.
1st software limit switch plus
RESET
_always 100000000 –
–
DOUBLE
36120 POS_LIMIT_MINUS2
mm,
deg.
2nd software limit switch minus
RESET
_always –100000000 –
–
DOUBLE
36130 POS_LIMIT_PLUS2
mm,
deg.
2nd software limit switch plus
RESET
_always 100000000 –
–
DOUBLE
36200 AX_VELO_LIMIT
mm/min,
rev/min
Threshold value for velocity monitoring
(control parameter set no.): 0 ... 5
NEW CONF
_always 11500.,
11500.,
11500., 11500., ...
0.0 plus DOUBLE
36300 ENC_FREQ_LIMIT
Hz
Encoder limit frequency
POWER ON
_always 300000
0
plus
DOUBLE
36302 ENC_FREQ_LIMIT_LOW
%
Encoder limit frequency at which encoder is switched on
again. (Hysteresis)
NEW CONF
_always 99.9
0
100
DOUBLE
36310 ENC_ZERO_MONITORING
–
Zero mark monitoring (encoder no.): 0,1
0: Zero mark monitoring off, encoder HW monitoring on
1–99, >100: Number of recognized zero mark errors
during monitoring
100: Zero mark monitoring off, encoder HW monitoring off
NEW CONF
_always 0,
0
0.0
plus
DWORD
36400 CONTOUR_TOL
mm,
deg.
Contour monitoring tolerance band
NEW CONF
_always 1.0
***
***
DOUBLE
36500 ENC_CHANGE_TOL