Connected load
Table 1–1 Connected load
Parameter
Min. Typ. Max. Unit
Supply voltage
20.4
24
28.8
V
Ripple
3.6
Vss
Current consumption from 24 V
2
A
Power dissipation of CNC
48
W
Start-up current
4
A
Note: The 24V DC voltage must be generated as a functional extra-low voltage
with safe electrical isolation (to EN60204-1, Section 6.4, PELV).
Weight
Table 1–2 Weight
Component Weight
[g]
CNC 2120
circa
Dimensions
Table 1–3 Component dimensions
Component Dimensions
LxWxD
[mm]
CNC
400 x 250 x 57.6
Environmental operating conditions
Table 1–4 Environmental operating conditions
Parameter
Temperature range
(horizontal mounting and
convection)
0….55
°
C (for box)
;
0….45
°
C (for display surface)
Permissible relative humidity
5…95% without condensation
Air pressure
860 ... 1,060 hPa
The operating conditions refer to EN60204-1.
Installation in a housing (e.g. cubicle) is absolutely necessary for operation.
Transport and storage conditions
Table 1–5 Transport and storage conditions
Parameter
Temperature range
-20 ... 60
°
C
Permissible relative air humidity
5 ... 95 % without condensation
Air pressure
700 ... 1,060hPa
Transport height
–1,000 ... 3,000m
Free fall in transport package
≤
0.5m
Protection class
Class of protection I according to IEC 529
The control must be equipped with a grounding conductor terminal.
Protection against ingress of solid foreign bodies and water according to ICE
529:
For CNC system: Front: IP54 Rear: IP20