Start-Up
2-26
SINUMERIK 801
Start-Up
2.3.7 Digital inputs/outputs X100 (DIN0)
~
X101 (DIN1), X200 (DOUT0) ... X201
(DOUT1)
General
There are 16 digital inputs and 12 digital outputs in all. Connector designation:
10 pin Mini-Combicon plug connector.
Table 2-15 Pin assignment for connectors X100
~
X101
Pin Signal
X100
Signal type
Pin Signal
X101
Signal type
1 n.c.
1 n.c.
2 Limit
X+
DI
2
T1
DI
3 Limit
X-
DI
3
T2
DI
4 Ref.
X
DI
4
T3
DI
5 Limit
Z+
DI
5
T4
DI
6 Limit
Z-
DI
6
T5
DI
7 Ref.
Z
DI
7
T6
DI
8 FootPed
DI
8 User
in1
DI
9 E-Stop
DI
9 User
in2
DI
10 M24
VI
10 M24
VI
* In the list above, high signal level refers to 15 …30 VDC, current drain 2 …
15 mA and low level -3 … 5 VDC.
Signal type
VI
Voltage
input
DI
Input (24 V signal)
Table 2–16 Electrical parameters of the digital inputs
Parameter Value
Unit
Note
“1” signal, voltage range
15 ... 30
V
“1” signal, current consumption
2 ... 15
mA
“0” signal, voltage range
–3 ... 5
V
Or input open
Signal delay 0
Æ
1
0.5 ... 3
ms
Signal delay 1
Æ
0
0.5 ... 3
ms
Notice
See Section 3.2 “ Input/Output Configuration” for definitions of X100 ... X101
input signals.
Summary of Contents for Sinumerik 801
Page 1: ...Start Up 11 2005 Edition sinumerik SIEMENS SINUMERIK 801 ...
Page 6: ......
Page 8: ......
Page 16: ......
Page 78: ......
Page 81: ...Services Diagnosis and Data Saving SINUMERIK 801 5 3 Start Up Fig 5 4 ...
Page 105: ...A5E00702069 ...