Start-Up
SINUMERIK 801
2-27
Start-Up
Table 2-17 Pin assignment for connectors X200
~
X201
Pin Signal
X200
Signal type
Pin Signal
X201
Signal type
1 P24 VI
1 P24
VI
2 S-CW DO
2 User
out1 DO
3 S-CCW
DO
3 User
out2
DO
4 T-CW DO
4 User
out3 DO
5
T-CCW
DO
5 User
out4
DO
6 Cooling
DO
6
n.c.
7 Lubric
DO
7
n.c.
8 S-Brake
DO
8
n.c.
9 Chuck
DO
9
n.c.
10 M24
VI
10 M24
VI
* In this list, high signal level refers to the 24VDC, current leakage less than
2mA with a simultaneity factor of 0.5.
Signal
type
VI
Voltage
input
DO
Digital output (24 V signal)
Table 2–18 Electrical parameters of the digital outputs
Parameter Value
Unit
Note
“1” signal, nominal voltage
Voltage drop
24
max. 28.8
V
V
“1” signal, output current
0.5
A
Simultaneity factor
0.5 per 12 outputs
“0” signal, leakage current
max. 2
mA
Notice
See Section 3.2 “Input/Output Configuration” for definitions of X200 ... X201
output signals.