Setting Up
5-2
SINUMERIK 801
Start-Up
* 2: single-edge evaluation, for locking the reference point in the rising edge of
the proximity switch; 4: double-edge evaluation, for locking the referece point
in the intermediate point between rising and falling eges.
Notice
Even if the function “record reference point” has been activated, reference
point must be approached again under following circustances, otherwise
collision might be resulted!
1. After system power up with saved data
a
)
After machine operator selects on the operator panel to
“
power up with
saved data
”
(corresponding alarm# 004062).
b
)
System will be powered up automatically with saved data after it has been
dead for a long period and battery for internal data savings run out of
power. (corresponding alarm# 004065)
2. After system power-off, the actual position of the axis concerned has
been moved out of maintenance or other reasons.
Parameterization for stepper motors:
MD Designation
Unit Axis
Input
value
Description
31020
ENC_RESOL
IPR
X
,
Z
1000
Encoder
markings per
revolution
(encoder no.)
31400
STEP_RESOL
IPR
X
,
Z
1000
Steps per
stepping motor
revolution
Mechanical parameters for the driving system:
MD Designation
Unit
Axis
Input
value
Description
31030 LEADSCREW_
PITCH
mm
X
,
Z
5
Pitch of
leadscrew
31050 DRIVE_AX_RATIO
_DENUM[0 ... 5]
-
X
,
Z
40
Denominator
load gearbox
(control
parameter No.)
31060 DRIVE_AX_RATIO
_NUMERA[0
…
5]
-
X
,
Z
50
Numerator load
gearbox (control
parameter set
No.)
Note:
After determining the mechanical parameters,
set the axis speed. For
stepper motors, the motor speed shall be determined according to its
frequency-torque characteristics: motor speed
=
axis speed/leadscrew
pitch/reduction ratio.
Summary of Contents for Sinumerik 801