Technical Appendix
7-1
SINUMERIK 801
Start-Up
_always 1
–1
31
DWORD
34200 ENC_REFP_MODE
–
Type of position measuring system
0: No ref. point appr.; if an absolute encoder exists:
REFP_SET_POS accepted
1: Zero pulse (on encoder track)
POWER ON
_always 1
0
6
BYTE
34210 ENC_REFP_STATE
–
0:
Function “record reference point” inactive. Reference
point must be approached again next time when
normal system power-up.
1: Fucntion “record refrence point” activated. After
reference point has been approached, this machine
data is changed to 2 automatically. If the reference
point has been saved before power-off, next time
when power up, system will record position and
reference point of that axis saved, so no reference
point approach is required.
POWER ON
_always 0
1
2
DWORD
35010 GEAR_STEP_CHANGE_ENABLE
–
Gear change possible. Spindle has several gear steps
POWER ON
_always 0
***
***
BOOLEAN
35040 SPIND_ACTIVE_AFTER_RESET
–
Own spindle reset
POWER ON
_always 0
***
***
BOOLEAN
35100 SPIND_VELO_LIMIT
rev/min
Maximum spindle speed
POWER ON
_always 10000
0.0
plus
DOUBLE
35110 GEAR_STEP_MAX_VELO
rev/min
Maximum speed for gear change (gear stage no.): 0..5
NEW CONF
_always
500, 500, 1000,
2000, 4000, 8000
0.0 plus DOUBLE
35120 GEAR_STEP_MIN_VELO
rev/min
Minimum speed for gear change (gear stage no.): 0..5
NEW CONF
_always
50, 50, 400, 800,
1500, 3000
0.0 plus DOUBLE
35130 GEAR_STEP_MAX_VELO_LIMIT
rev/min
Maximum speed of gear stage (gear stage no.): 0 ... 5
NEW
CONF
_always
500, 500, 1000, 2000,
4000, 8000
0.0 plus
DOUBLE
35140 GEAR_STEP_MIN_VELO_LIMIT
rev/min
Minimum speed of gearsetp (gear stage no.): 0 ... 5
NEW CONF
Summary of Contents for Sinumerik 801
Page 1: ...Start Up 11 2005 Edition sinumerik SIEMENS SINUMERIK 801 ...
Page 6: ......
Page 8: ......
Page 16: ......
Page 78: ......
Page 81: ...Services Diagnosis and Data Saving SINUMERIK 801 5 3 Start Up Fig 5 4 ...
Page 105: ...A5E00702069 ...