2-15
SINUMERIK 802C
6FC5 597–3AA20–0BP2 (01.02)
Installing the Control System
2.1
Installing and removing the SINUMERIK 802C
!
Warning
Before performing any installation work, always first make sure that the system is disconnec-
ted from the mains!
The modules contain electrostatically sensitive devices.
It must be ensured that persons without ESD protection never touch printed circuit boards or
components when handling operator and machine control panels.
Approach
Prior to installation, the machine control panel can be provided with a spindle override switch
and an emergency stop button. If these are not required, the openings must be covered with
the supplied self–adhesive covers.
1. Mount the spindle override switch.
2. Install the operator panel and the machine control panel.
3. Connect the panel using ribbon cable.
4. Install the DIN rail.
5. Connect the ENC and DI/O components.
Note
If you want to connect several DI/O16 components, it may be necessary to remove the right–
hand connector from the housing.
6. Slide the components onto the DIN rail, tilt it down and screw it tight.
Removing the control system
The control components are removed as described above in the reverse order.
2
Summary of Contents for SINUMERIK 802C
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802C ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802C 6FC5 597 3AA20 0BP2 01 02 notice ...
Page 40: ...Installing the Drives 3 40 SINUMERIK 802C 6FC5 597 3AA20 0BP2 01 02 ...
Page 138: ...Index Index 138 SINUMERIK 802C 6FC5 597 3AA20 0BP2 01 02 notice ...
Page 140: ......