Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Depending on the reason for this alarm being triggered, the following remedial measures should be undertaken:
- Handwheel override: Cancel the motion overlay and avoid this or keep it smaller when the program is repeated.
- Transformation: Check the preset/programmed work offsets (current frame). If the values are correct, the tool holder
(fixture) must be moved in order to avoid triggering the same alarm when the program is repeated, which would again
cause the program to be canceled.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
10621
[Channel %1: ] Axis %2 rests on software limit switch %3%4
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = String
%4 = The axis of the software limit switch is only output if different from the traversing axis.
Explanation:
The specified axis is already positioned at the displayed software end delimiter.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Check machine data MD36110 $MA_POS_LIMIT_PLUS/
MD36130 $MA_POS_LIMIT_PLUS2 and MD36100 $MA_POS_LIMIT_MINUS/MD36120 $MA_POS_LIMIT_MINUS2 for
the software limit switches.
Shut down in JOG mode from the software limit switch.
Please inform the authorized personnel/service department.
Machine data:
Check whether the 2nd software limit switch has been selected in the.axis-specific interface signals: "DB380x DBX1000.3
(2nd software limit switch plus) and DB380x DBX1000.2 (2nd software limit switch minus).
Programm
continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
10630
[Channel %1: ] Block %2 axis %3 at working area limit %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle number
%4 = String (+ or -)
Explanation:
The specified axis violates the working area limitation. This is recognized only in the main run either because the minimum
axis values could not be measured before the transformation or because there is a motion overlay.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Program other motion or do not perform overlaid motion.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
10631
[Channel %1: ] Axis %2 rests at working area limit %3%4
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = String (+ or -)
%4 = The axis of the working area limitation is only output if different from the traversing axis.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
100
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2