12250
[Channel %1: ] Block %2 nested macro %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Explanation:
The macro technique supplies a 1-line instruction or series of instructions with a new identifier by means of the keyword
DEFINE. No further macro may be contained in the string of instructions (nesting). Example: N10 DEFINE MACRO1 AS
G01 G91 X123 MACRO2 F100
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction
pointer positions on the incorrect block.
Nested macros must be replaced by the full program information.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
12260
[Channel %1: ] Block %2 too many initialization values specified %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Explanation:
In the initialization of an array (array definition and value assignments to individual array elements) there are more
initialization values than array elements. Example: N10 DEF INT OTTO[2,3]=(..., ..., {more than 6 values})
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction
pointer positions on the incorrect block.
Check the NC program to establish whether:
1. During array definition the number of array elements (n,m) was indicated correctly (DEF INT FIELDNAME[n,m] e.g. an
array with 2 lines and 3 columns: n=2, m=3). 2. During initialization the value assignments have been made correctly
(values of the individual field elements separated by comma, decimal point for variables of the type REAL).
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
12261
[Channel %1: ] Block %2 initialization of %3 not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Explanation:
Frame type variables cannot be initialized in the definition. Example: DEF FRAME LOCFRAME = CTRANS(X,200)
Equally, no default values can be programmed for axes in the program run during field initialization via SET.
A REDEF instruction with PRLOC is only permitted for setting data,
but not for machine data or variables.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
IPerform initialization in separate block in the execution part of the program: DEF FRAME LOCFRAME LOCFRAME =
CTRANS(X,200)
When using for axis variables:
Replace DEF AXIS AXIS_VAR [10] AXIS_VAR [5] = SET (X, , Y) by: DEF AXIS AXIS_VAR [10] AXIS_VAR [5] = X
AXIS_VAR [7] = Y
If REDEF ... INIRE, INIPO, INICF, PRLOC changes the behavior of a GUD, LUD etc., then the MD11270
$MN_DEFAULT_VALUES_MEM_MASK must equal 1.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
149