Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
- Modify part program.
- Reduce the offset in tool direction to zero.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14199
[Channel %1: ] Block %2 illegal plane change for tool with diameter component
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
If a tool has a wear or length component which is evaluated as a diameter for the facing axis (bit 0 and/or bit 1 in MD20360
$MC_TOOL_PARAMETER_DEF_MASK is set) and bit 2 of this MD is also set, this tool may only be used in the plane
active on tool selection. A plane change results in an alarm.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Reset bit 2 in MD20360 $MC_TOOL_PARAMETER_DEF_MASK.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14200
[Channel %1: ] Block %2 negative polar radius
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In the endpoint specification of a traversing block with G00, G01, G02 or G03 in polar coordinates, the polar radius entered
for the keyword RP=... is negative.
Definition of terms:
- Specification of end of block point with polar angle and polar radius, referring to the current pole (preparatory functions:
G00/G01/G02/G03).
- New definition of the pole with polar angle and pole radius, referring to the reference point selected with the G function.
G110 ... last programmed point in the plane, G111 ... zero point of the current work, G112 ... last pole
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct NC part program - permissible inputs for the pole radius are only positive absolute values that specify the distance
between the current pole and the block end point. (The direction is defined by the polar angle AP=...).
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14210
[Channel %1: ] Block %2 polar angle too large
Parameters:
%1 = Channel number
%2 = Block number, label
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
201