Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
All reload buffers are cleared on POWER ON.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
14602
[Channel %1: ] Block %2 timeout while reloading from external.
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No connection could be made to the HMI while reloading external subprograms (EXTCALL) or executing from external
drives) within the monitoring time set in MD10132 $MN_MMC_CMD_TIMEOUT.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check the connection to the HMI
- Increase MD10132 $MN_MMC_CMD_TIMEOUT.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
14603
[Channel %1: ] Block %2 timeout during execution from external source.
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
If a program is selected for execution from external source, it will be expected that the first part program line can be read
from the reload buffer within 60s after part program start.
Otherwise, part program processing will be canceled with alarm 14603 due to the assumption that the connection to the
HMI or the external device is faulted.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check the connection to the HMI and repeat selection of the program that is to be executed from external source.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
- Acknowledge the alarm by pressing the RESET key
- Repeat program selection
- Start the part program
14610
[Channel %1: ] Block %2 compensation block not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An alarm was output which could be eliminated basically via program correction. Since the error occurred in a program
which is processed from external, a compensation block/program correction is not possible.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Cancel program with reset.
- Correct program on HMI or PC.
- Restart reloading (possibly with block search and interrupt location).
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
210