Remedy:
Correct the part program - max. 16 auxiliary functions, max. 5 M functions per NC block, max. 1 auxiliary function per
group.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14780
[Channel %1: ] Block %2 option '%3<OPTNX>' is not set.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Brief description of option
Explanation:
A non-released option has been used in the block.
The stated or an equivalent option is required to execute the action.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program, retrofit option.
In this context, please compare the available option data and/or (if available) the license image of your controller.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14781
[Channel %1: ] Block %2 motion synchronized action: %3 Option '%4<OPTNX>' is not set
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Brief description of option
Explanation:
Motion synchronized action: a non-enabled option was used.
The specified or an equivalent option is required to execute the action.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change motion synchronized action, retrofit option.
In this context, please compare the available option data and/or (if available) the license image of your control
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14782
[Channel %1: ] Block %2 non-active function used (identification %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Explanation:
A non-active function is used in the block
Code Short description
1 Transformation
2 Tool H numbers
3 3D protection areas
4 Tool management, multitools
5 COMPSURF and $MC_MM_NUM_SURF_LEVELS=0
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Modify part program.
- Activate function.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
221