Explanation:
If an encrypted program is loaded to the NCK, an NCK reset (restart) must be performed afterwards, because internal data
for efficient processing of the encrypted program are preprocessed during NCK power-up. The following problem has
occurred:
Error code 1: Error on read-in of program %4
Error code 2: There is not enough DRAM memory available for storing the preprocessed data.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Error code 1: Encrypt and load program %4 again. Then perform an NCK reset (restart).
Error code 2: Increase system SL 710-740, 802D, 828D: $MN_MM_T_FILE_MEM_SIZE.
Increase system SL 840 DI: $MN_MM_DRAM_FILE_MEM_SIZE.
Then perform an NCK reset (restart).
Programm
continuation:
Clear alarm with the RESET key. Restart part program
15179
Error when copying the file 'restorafs.inm', error ID %1
Parameters:
%1 = Error code
%2 = Is not used
%3 = Is not used
Explanation:
Copying the file 'restoreafs.inm' from the CF card into the active file system (to /_N_SYF_DIR) failed.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The restore file 'restoreafs.inm' was not executed. The file lies on the CF Card under /siemens/sinumerik/sys_cach/nck/
Remedy: Copy 'restoreafs.inm' via HMI to /_N_SYF_DIR/_N_RESTOREAFS_INM before the next restart, and then delete
or rename the file on the CF card to prevent the restore file being executed at every restart.
Programm
continuation:
Switch control OFF - ON.
15180
[Channel %1: ] Block %2: Error on editing program %3 as INI/DEF file.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Explanation:
Errors were found when processing an initialization program (INI file), or a GUD or macro definition file (DEF file).
The error message which is then displayed refers to the program specified here.
Reaction:
Alarm display.
Remedy:
Correct the initialization program (INI file), or the GUD or macro definition file (DEF file).
In connection with Alarm 12380 or 12460, also change the memory configuration.
Programm
continuation:
Clear alarm with the Delete key or NC START.
15182
[channel %1: ] cycle alarm from the modified SIEMENS cycle %3
Parameters:
%1 = Channel number
%2 = Is not used
%3 = Path and file name of the modified SIEMENS cycle
Explanation:
When executing a SIEMENS cycle modified by the user, a cycle alarm was output with SETAL() (see follow-up alarm in
the alarm output).
Since the SIEMENS cycle was modified by the user (e.g. machine manufacturer), the cause for the cycle alarm must be
determined / eliminated by the user who modified the cycle.
Reaction:
Interface signals are set.
Alarm display.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
232
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2