Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
16770
[Channel %1: ] Block %2 axis %3 no measuring system available
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Explanation:
One of the following spindle functions has been programmed, the position control requires:
SPCON,
SPOS, SPOSA,
COUPON,
G331/G332.
The position control requires at least one measuring system.
No measuring system has been configured in MD30200 $MA_NUM_ENCS of the programmed spindle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Retrofit a measuring system.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
16775
[Channel %1: ] Block %2 motion synchronous action: %3 axis %4 no measuring system available
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Axis name, spindle number
Explanation:
One of the following spindle functions has been programmed, the position control requires:
SPCON,
SPOS, SPOSA,
COUPON,
G331/G332.
The position control requires at least one measuring system.
No measuring system has been configured in MD30200 $MA_NUM_ENCS of the programmed spindle.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Retrofit a measuring system.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
16794
[Channel %1: ] Block %2 coupling of axis/spindle %3 prohibits reference point approach
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
254