16953
[Channel %1: ] For slave axis %2 SERUPRO not allowed, as master axis %3 not subject to axis/
spindle disable
Parameters:
%1 = Channel number
%2 = Slave axis name, following spindle number
%3 = Master axis name, master spindle number
Explanation:
Currently, the alarm occurs only in combination with the SERUPRO action. SERUPRO stands for search via program test.
SERUPRO is possible only with an active coupling, if the axis/spindle disable is active for all master axes/spindles of the
slave axis/spindle
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Set axis/spindle disable of the master axis
Programm
continuation:
Clear alarm with the RESET key. Restart part program
16954
[Channel %1: ] Block %2 programmed stop prohibited in stop delay area
Parameters:
%1 = Channel ID
%2 = Block number, label
Explanation:
In a program area (stop delay area) that is bracketed with DELAYFSTON and DELAYFSTOF, a program command was
used that causes a stop. No commands other than G4 are permissible that might cause a stop even though only shortly.
A stop delay area can also be defined by MD11550 $MN_STOP_MODE_MASK.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
MD11550 $MN_STOP_MODE_MASK and language command DELAYFSTON DELAYFSTOF
Programm
continuation:
Clear alarm with the RESET key. Restart part program
16955
[Channel %1: ] Stop in stop delay area is delayed
Parameters:
%1 = Channel ID
Explanation:
In a program area (stop delay area) that is bracketed by DELAYFSTON and DELAYFSTOF, an event has been detected
that causes a stop. The stop is delayed and executed after DELAYFSTOF. A stop delay area can also be defined by
MD11550 $MN_STOP_MODE_MASK.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
MD11550 $MN_STOP_MODE_MASK and language command DELAYFSTON DELAYFSTOF
Programm
continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
16956
[Channel %1: ] Program %2 cannot be started due to global start disable.
Parameters:
%1 = Channel ID
%2 = (path with program name)
Explanation:
The program selected in this channel cannot be started as "Global start disable" had been set.
Note:
PI "_N_STRTLK" sets the "Global start disable" and PI "_N_STRTUL"
deletes the "Global start disable".
The alarm is switched on with MD11411 $MN_ENABLE_ALARM_MASK bit 6.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
268
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2