17000
[Channel %1: ] Block %2 maximum number of symbols exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The maximum number of symbols defined by machine data MD28020 $MC_MM_NUM_LUD_NAMES_TOTAL has been
exceeded.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify machine data
- Reduce the number of symbols (variables, subroutines, parameters)
Programm
continuation:
Clear alarm with the RESET key. Restart part program
17001
[Channel %1: ] Block %2 no memory left for tool/magazine data
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The number of the following tool/magazine data variables in the NC is specified using machine data:
- Number of tools + number of grinding data blocks: MD18082 $MN_MM_NUM_TOOL
- Number of cutting edges: MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA
Tools, grinding data blocks, cutting edges can be used independently of the tool management.
The memory for the following data is available only if the corresponding bit has been set in MD18080
$MN_MM_TOOL_MANAGEMENT_MASK.
- Number of monitoring data blocks: MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA
- Number of magazines: MD18084 $MN_MM_NUM_MAGAZINE
- Number of magazine locations: MD18086 $MN_MM_NUM_MAGAZINE_LOCATION
The following variable is determined by the software configuration: Number of magazine spacing data blocks: P2 permits
32 such spacing data blocks.
Definition:
- 'Grinding data blocks': Grinding data can be defined for a tool of type 400 to 499. A data block of this type occupies as
much additional memory as that provided for a cutting edge.
- 'Monitoring data blocks': Each cutting edge of a tool can be supplemented with monitoring data.
- If the alarm occurs while writing one of the parameters $TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether machine data MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC /
MD18076$MN_MM_NUM_LOCS_WITH_DISTANCE has been set correctly.
MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC defines the number of different Index1 statements that may be
made for an Index2 value.
MD18076 $MN_MM_NUM_LOCS_WITH_DISTANCE defines the number of different buffer locations that may be named
in Index2.
If a multitool is to be generated or its locations, the alarm indicates that either more multitools need to be generated than
are permitted by the setting of MD18083 $MN_MM_NUM_MULTITOOL or, if the alarm occurs when the multitool locations
are being generated, that more multitool locations need to be generated than is permitted by the setting of MD18085
$MN_MM_NUM_MULTITOOL_LOCATIONS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify machine data
- Modify NC program, i.e. reduce number of rejected variable.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.