17010
[Channel %1: ] Block %2 no memory left
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
When executing/reading files from the active working memory, it was found that there is not enough memory space (e.g.
for large multidimensional arrays or when creating tool offset memory).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Make arrays smaller or make more memory space available
for memory management of subroutine calls, tool offsets and user variables (machine data MM_...).
See /FB/, S7 Memory Configuration
Programm
continuation:
Clear alarm with the RESET key. Restart part program
17018
[Channel %1: ] Block %2 incorrect value for parameter %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Parameter name
Explanation:
An incorrect value has been assigned to the stated parameter.
Only the following values are permissible for the parameter $P_WORKAREA_CS_COORD_SYSTEM
=1 for workpiece coordinate system
=3 for settable zero system.
Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Assign another value.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
17020
[Channel %1: ] Block %2 illegal array index 1
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
General:
Read or write access has been programmed to an array variable with an illegal 1st array index. The valid array indices
must lie within the defined array size and the absolute limits (0 - 32,766).
PROFIBUS I/O:
An illegal slot / I/O area index was used while reading/writing data.
Cause:
1.: Slot / I/O area index >= max. number of available slot / I/O areas.
2.: Slot / I/O area index references a slot / I/O area that has not been configured.
3.: Slot / I/O area index references a slot / I/O area that has not been released for system variables.
The following applies specifically: If the alarm occurs while writing one of the parameters
$TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC has been set correctly.
MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC defines the number of different Index1 statements that may be
made for an Index2 value.
If an MT number is programmed, the value may collide with a previously defined T number or a previously defined magazine
number.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
272
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2