Reaction:
Interface signals are set.
Alarm display.
Remedy:
Deselect fixed-point approach in JOG, or previously deselect the transformation with TRAFOOF or disband the coupling.
Programm
continuation:
Clear alarm with the Delete key or NC START.
17812
[Channel %1: ] Axis %2 fixed-point approach in JOG: Fixed point %3 changed
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Fixed-point number
Explanation:
'Fixed-point approach in JOG' is active for the axis, but another fixed point has been selected, or the fixed-point approach
has been deactivated. The approach motion is canceled.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Trigger JOG motion again.
Programm
continuation:
Clear alarm with the Delete key or NC START.
17813
[Channel %1: ] Axis %2 fixed-point approach in JOG and override motion active
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
'Fixed-point approach in JOG' is active for the axis, but another offset motion - for example a synchronization offset
$AA_OFF - has been interpolated simultaneously.
The position of the selected fixed-point is not reached if offset values are changed during the traversing motion.
The target point then becomes "fixed-point po change in offset value".
The end point will be reached if the traversing motion is restarted after the offset value has been changed.
(For example: incremental traversing in which the traversing motion stops intermittently).
Reason:
Restarting the motion takes the current offset value into account.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Trigger JOG motion again.
Programm
continuation:
Clear alarm with the Delete key or NC START.
17814
[Channel %1: ] Axis %2 fixed-point position not available
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Number of fixed-point position
Explanation:
No fixed-point position is available for the fixed point selected in JOG mode. See MD30610 $MA_NUM_FIX_POINT_POS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Adapt MD30610 $MA_NUM_FIX_POINT_POS and, if necessary, MD30600 $MA_FIX_POINT_POS[].
Deselect fixed-point approach or select a valid fixed point, and restart the JOG motion.
Programm
continuation:
Clear alarm with the Delete key or NC START.
17815
Indexing axis %1 fixed point %2 unequal indexing position
Parameters:
%1 = Axis number
%2 = Array index of machine data
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
289