Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify program or set MD18600
$MN_MM_FRAME_FINE_TRANS to 1.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
18310
[Channel %1: ] Block %2 frame: illegal rotation
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Rotations are not possible with NCU global frames.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
18311
[Channel %1: ] Block %2 frame: illegal instruction
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An attempt was made to read or write a frame which does not exist.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
18312
[Channel %1: ] Block %2 frame: fine shift not configured
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Fine shift must be configurd with G58 and G59.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify machine data.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
18313
[Channel %1: ] Block %2 frame: illegal switchover of geometry axes
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
It is not allowed to change the geometry axis assignment because the current frame contains rotations.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
297