Explanation:
The function request by PLC via DBB30 interface could not be executed. The cause is specified by the error code.
Error codes:
- Error code 1 : internal use
- Error code 2 : internal use
- Error code 3 : internal use
- Error code 4 : internal use
- Error code 5 : Switchover to command axis not possible
- Error code 6 : Switchover to PLC axis not possible
- Error code 20 : internal use
- Error code 21 : internal use
- Error code 22 : internal use
- Error code 23 : MD 30132 IS_VIRTUAL_AX has been set
- Error code 50 : internal use
- Error code 51 : internal use
- Error code 70 : internal use
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy conflict.
Programm
continuation:
Clear alarm with the Delete key or NC START.
22296
[Channel %1: ] Spindle %2 Error on gear stage change (cause: error code %3)
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Error code
Explanation:
An error occurred during gear stage change. The cause is specified by the error code.
Error codes:
- Error code 1 : internal use
- Error code 2 : internal use
- Error code 3 : internal use
- Error code 4 : internal use
- Error code 5 : Switchover to command axis not possible
- Error code 6 : Switchover to PLC axis not possible
- Error code 20 : internal use
- Error code 21 : internal use
- Error code 22 : internal use
- Error code 23 : MD 30132 IS_VIRTUAL_AX has been set
- Error code 50 : internal use
- Error code 51 : internal use
- Error code 70 : internal use
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy conflict.
Programm
continuation:
Clear alarm with the Delete key or NC START.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
335