Reaction:
NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Repeat entry with correct value and then Reset.
Programm
continuation:
Restart part program. Clear alarm with the RESET key in all channels of this mode group. Restart part program.
26018
Axis %1 setpoint output drive %2 used more than once
Parameters:
%1 = Axis name, spindle number
%2 = Drive number
Explanation:
The same setpoint assignment has been allocated more than once.
MD30110 $MA_CTRLOUT_MODULE_NR contains the same value for different axes.
PROFIdrive: The stated MDs contain the same values for different axes, or different entries in
$MN_DRIVE_LOGIC_ADDRESS contain the same values.
Reaction:
Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Avoid dual assignment of the setpoint by correcting MD30110
$MA_CTRLOUT_MODULE_NR. Also check the selected bus type MD30100 $MA_CTRLOUT_SEGMENT_NR.
Programm
continuation:
Switch control OFF - ON.
26019
Axis %1 encoder %2 measurement not possible with this controller module
Parameters:
%1 = NC axis number
%2 = Encoder number
Explanation:
If the MD MD13100 $MN_DRIVE_DIAGNOSIS[8] contains a value not equal to zero, then the control has found at least
one control module which does not support measuring. Measuring was programmed from the part program for the
associated axis.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
If possible, modify the measuring motion such that the axis concerned does not have to travel; do not program this axis
in the MEAS block again. However, it is then no longer possible to query a measured value for this axis. Otherwise,
exchange the controller module for one that supports measuring. See MD13100 $MN_DRIVE_DIAGNOSIS[8].
Programm
continuation:
Clear alarm with the RESET key. Restart part program
26020
Axis %1 encoder %2 hardware fault %3 during encoder initialization
Parameters:
%1 = Axis name, spindle number
%2 = Encoder number
%3 = Error fine coding
Explanation:
Error during initialization or access of encoder.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
351