5.3
Cycle alarms
To view detailed description about individual alarms directly on the PPU, proceed as follows:
1.
Press this key on the PPU to enter the alarm operating area.
2.
Select the desired alarm.
3.
Press this key to open the online help for the selected alarm.
61000
%[[Channel %1: ] Block %2: %]No tool offset active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
D-correction must be programmed before the cycle call.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61001
[Channel %1: ] Block %2: Thread pitch incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter for the thread size or setting for the pitch (contradict each other).
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61002
%[[Channel %1: ] Block %2: %]Type of machining incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Remedy:
Modify VARI parameter.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61003
%[[Channel %1: ] Block %2: %]No feed programmed in cycle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
363