61008
[Channel %1: ] Block %2: No tool active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Alarm triggered by following cycles:
Remedy:
Select a tool.
61009
[Channel %1: ] Block %2: Active tool number = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No tool (T) has been programmed before the cycle call.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program tool (T).
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61010
[Channel %1: ] Block %2: Finishing allowance too large
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The finishing allowance for the base is greater than the total depth.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reduce finishing allowance.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61011
[Channel %1: ] Block %2: Scaling not permissible
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
A scale factor is active which is illegal for this cycle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify scale factor.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61012
%[[Channel %1: ] Block %2: %]Different scaling in planes
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
365