Remedy:
--
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61013
[Channel %1: ] Block %2: Basic settings were changed, program cannot be executed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
The basic settings are not compatible with the generated program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check and, if necessary, change the basic settings.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61014
[Channel %1: ] Block %2: Return plane exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check parameter RTP.
61015
[Channel %1: ] Block %2: Contour is not defined
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61016
[Channel %1: ] Block %2: System frame for cycles missing
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Set MD 28082: MM_SYSTEM_FRAME_MASK, Bit 5=1.
61017
%[[Channel %1: ] Block %2: %]Function %4 not present in NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
366