Programm
continuation:
Clear alarm with the RESET key. Restart part program
61044
%[[Channel %1: ] Block %2: %]Illegal character(s) in file name: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove illegal character from file name
Permitted characters are: letters, figures, underscore, slash with path name
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61045
[Channel %1: ] Block %2: Job list not found: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The specified job list could not be found.
Check name and contents of job list.
The job list must be in the same workpiece as the part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61046
[Channel %1: ] Block %2: Part program not found in job list: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Part program (main program) not found in specified job list in respective channel.
Check name and contents of job list.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61047
[Channel %1: ] Block %2: Label name %4 too long
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
374
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2