Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- select shorter label name
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61048
[Channel %1: ] Block %2: Multi-channel data not found in job list: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Multi-channel data not found in job list.
Correct job list.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61049
[Channel %1: ] Block %2: 1st spindle not programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program 1st spindle in the mask.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61050
[Channel %1: ] Block %2: Spindle programmed twice
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The same spindle was programmed twice.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Leave 2nd spindle empty or program other spindle.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61051
%[[Channel %1: ] Block %2: %]Program name assigned twice
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The same program name was assigned twice.
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2