Explanation:
This alarm is used for various purposes.
Please refer to the alarm text.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Depends on alarm text
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61099
[Channel %1: ] Block %2: Internal cycle error (%4)
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61101
%[[Channel %1: ] Block %2: %]Reference point defined incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
With an incremental specification of the depth, either different values have to be selected for the reference point (reference
plane) and the retraction plane, or an absolute value must be specified for the depth.
When machining in the "manual machine" area, the following setting data must be checked and adapted to the machining.
SD 55260 $SCS_MAJOG_SAFETY_CLEARANCE (value greater than zero)
SD 55261 $SCS_MAJOG_RELEASE_PLANE
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61102
%[[Channel %1: ] Block %2: %]No spindle direction programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Parameter SDIR (or SDR in CYCLE840) must be programmed.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2