61251
[Channel %1: ] Block %2: Width across flats/edge length too large
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The width across flats/edge length is too large.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Decrease key width/edge length.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61252
[Channel %1: ] Block %2: Chamfer/radius too large
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Chamfer/radius is too large.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Decrease chamfer/radius.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61253
[Channel %1: ] Block %2: No finishing allowance programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No finishing allowance has been entered.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm a finishing allowance.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61254
[Channel %1: ] Block %2: Error while traveling to fixed stop
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Error on travelling to fixed stop.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
specify another Z1 position for gripping the counterspindle.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
416
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2