Programm
continuation:
Clear alarm with the RESET key. Restart part program
61267
[Channel %1: ] Block %2: Plane infeed too large, residual corners remain
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In face milling, the plane infeed must not exceed 85%.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select a smaller plane infeed, as otherwise residual corners will be left over.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61268
[Channel %1: ] Block %2: Illegal machining direction, residual corners are left over.
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In face milling, the machining direction does not match the selected delimitations.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The machining direction must be selected to match the delimitations.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61269
[Channel %1: ] Block %2: External tool diameter too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Incorrect tool definition.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check angle and diameter of the tool used.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61270
%[[Channel %1: ] Block %2: %]Chamfer width too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Chamfer width selected too small.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Increase the chamfer width.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
420
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2