61271
%[[Channel %1: ] Block %2: %]Chamfer width greater than tool radius
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Chamfer width larger than tool radius.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a larger tool.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61272
%[[Channel %1: ] Block %2: %]Insertion depth too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Insertion depth on chamfering too small.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Increase the insertion depth.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61273
%[[Channel %1: ] Block %2: %]Insertion depth too large
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Insertion depth on chamfering too large.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Decrease the insertion depth.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61274
%[[Channel %1: ] Block %2: %]Invalid tool angle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Invalid tool angle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check tool angle
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
421