61299
[Channel %1: ] Block %2: No work offset entered for counterspindle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No work offset has been entered for the counterspindle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify a work offset for the counterspindle in the program header or under Settings.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61300
[Channel %1: ] Block %2: Probe defective
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61301
[Channel %1: ] Block %2: Probe not switching
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The measuring distance was completely traversed, but no switching signal was generated at the measuring input.
Remedy:
-Check measuring input.
-Check measuring distance.
-Probe defective.
61302
[Channel %1: ] Block %2: Probe - collision
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The measuring probe collided with an obstacle when being positioned.
Remedy:
- Check spigot diameter (may be too small)
- Check measuring distance (may be too long)
61303
[Channel %1: ] Block %2: Safety margin exceeded %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The measuring result differs greatly from the specified value.
Remedy:
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3:
- Check setpoint value and parameter _TSA
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4:
- Check setpoint value and parameter TSA
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
428