Remedy:
A traversing path for measuring is generated with a size that can be specified. It describes the maximum distance before
and after the expected switching position (workpiece edge) and must have a value greater than 0.
In the AUTOMATIC operating mode:
For 840D sl - to SW 2.6 SP1 and for 828D - to SW 4.3 :
- Check parameter_FA
For 840D sl - from SW 2.7 and for 828D - from SW 4.4 :
- Check parameter DFA
In the JOG mode:
For 840D sl - from SW 2.7 and for 828D - from SW 4.4 :
- Check parameters MD51786: $MNS_J_MEA_T_PROBE_MEASURE_DIST, MD51752:
$MNS_J_MEA_M_DIST_TOOL_LENGTH and MD51753: $MNS_J_MEA_M_DIST_TOOL_RADIUS
61309
[Channel %1: ] Block %2: Check probe type
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Remedy:
Measurement of workpiece:
Check tool type of measuring probe in TOOLMAN.
When measuring workpiece milling, it is preferred to use tool types 710, 712, 713 or 714. But a type 1xy can also be used.
Type 710 is permitted for workpiece measurement in all measuring cycles. Types 712, 713 and 714 are intended for
special measuring tasks.
When measuring workpiece turning, it is preferred to use tool type 580. However, a type 1xy can also be used, but only
if setting data $SC_TOOL_LENGTH_TYPE=2 is set.
Measurement of tool:
For measuring tool milling, no permissible tool probe type is entered in SD54633 $SNS_MEA_TP_TYPE[S_PRNUM-1]
or SD54648 $SNS_MEA_TPW_TYPE[S_PRNUM-1] and/or
check the permissible working plane G17...G19 for tool type "Disk".
61310
[Channel %1: ] Block %2: Scale factor is active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Scale factor = scaling is active.
Remedy:
Switch off the active scale factor in the program. Measuring is not possible with an active scale factor.
61311
[Channel %1: ] Block %2: No D number active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No tool offset for the measuring probe (for workpiece measurement) or no tool offset for the active tool (for tool
measurement) is selected.
Remedy:
Select the tool's tool edge number D.
61312
[Channel %1: ] Block %2: Check measuring cycle number
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Remedy:
Measuring cycle called is impermissible...
61313
[Channel %1: ] Block %2: Check probe number
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
430