61422
[channel %1: ] block %2: parameter measuring variant incorrect - error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Causes of error: See error code %4
A -> CYCLE996 _MVAR = 9x identifiers CYCLE996 measure kinematics or
A -> CYCLE996 _MVAR ONES digit outside the value range 0..4
B -> CYCLE996 _MVAR (parameter for normalization) HUNDRED THOUSANDS digit (dec6) or
B -> CYCLE996 ONE MILLION digit(dec7) outside the value range 0..3
C -> CYCLE996 Measurement version "compute kinematics" active, but rotary axes 1 and/or 2 not measured (see
also parameter _OVR[40])
or rotary axis 2 exists and no rotary axis vectors (V2xyz) are set up.
D -> CYCLE996 _MVAR TEN THOUSANDS digit (parameter rotary axis 1,2 or vector chain open, closed) outside the
value range 0..3
1 -> CYCLE9960 S_MVAR ONES to TEN THOUSANDS digit outside the value range
2 -> CYCLE9960 S_MVAR S_MVAR TENS digit not compatible with the ONES DIGIT
3 -> CYCLE9960 S_MVAR TENS digit outside the value range 0,2
61423
[Channel %1: ] Block %2: Parameter %4 not agreed or not created
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Causes of error: See error code %4
For 840D sl - up to SW 2.6 SP1 and for 828D - up to SW 4.3 :
1. Parameter CYCLE996 _TNUM incorrect or equals zero
2. No swivel data record created -> MD18088 = 0
For 840D sl - as from SW 2.7 and for 828D - as from SW 4.4 :
1. Parameter CYCLE996 S_TC incorrect or equals zero
2. No swivel data record created -> MD18088 = 0
For 840D sl - as from SW 4.7 SP1:
3 $NT_NAME? -> CYCLE996 System variable $NT_NAME not existing
4 TRAFO NO=0? -> CYCLE996 Trafo number = 0 ?
5 TRAFO TYP? -> CYCLE996 Transformation type unequal to 24,40,56
6 S_MVAR? -> CYCLE996 Trafo type OK, but incorrect call from CYCLE9960
7 TRAFO Roundaxis 3? -> CYCLE996 Transformation with 3rd rotary axis for kinematic measuring with CYCLE9960 not
allowed
1 (S_TNAME) -> CYCLE9960 Name of swivel data set or transformation not parameterized
2 (KC) -> CYCLE9960 No transformation on the basis of the kinematic chain set up
3 (TC) -> CYCLE9960 No swivel data set found
4 -> CYCLE9960 Compile Cycle E996 not set up
61424
[Channel %1: ] Block %2: Parameter %4 for diameter of calibration ball incorrect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
Check whether the correct diameter of the calibration ball is entered in parameter S_SETV,
or the correct probe ball radius is entered in the tool data of the current workpiece probe.
The mechanical deviation of the position of the current workpiece probe must be minimized by presetting.
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
446
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2