Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check if the program of the guide channel runs in the channel selected via the program of the following channel in
parameter partner channel.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61748
%[[channel %1: ] block %2: %]Machining plane different in guide and following channel
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Machining plane must be the same in guide and following channel.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61749
%[[channel %1: ] block %2: %]Technology different in guide and following channel
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Technology (cutting / residual, plunge-cutting / residual, plunge-turning / residual) must be the same in guide and following
channel.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61750
%[[channel %1: ] block %2: %]Machining different in guide and following channel
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Machining (rough cutting / finish cutting) must not be different in guide and following channel.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61751
%[[Channel %1: ] Block %2: %]The measuring system is different in the leading and following
channels
Parameters:
%1 = Channel number
%2 = Block number, label