61912
%[[Channel %1: ] Block %2: %]Error in spigot contour %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check programming of the spigot contour
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61913
%[[Channel %1: ] Block %2: %]Error in contour %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check programming of the contour
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61914
%[[Channel %1: ] Block %2: %]Too many contours specified
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check the number of contours
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61915
%[[Channel %1: ] Block %2: %]Cutter radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check the radius of the milling cutter in tool management
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
494
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2