Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Modify contour programming, replace G0 by G1
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61937
%[[Channel %1: ] Block %2: %]Pocket depth programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check parameter Z1
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61938
%[[Channel %1: ] Block %2: %]No starting point specified
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check parameter for specified starting point,
- for G17: XS, YS
- for G18: ZS, XS
- for G19: YS, ZS
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61939
%[[Channel %1: ] Block %2: %]No center point specified for circle
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check contour programming, particularly circular-path programming
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61940
%[[Channel %1: ] Block %2: %]Specified starting point programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label