61948
%[[Channel %1: ] Block %2: %]No material available for machining
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check programming of the contours
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61949
%[[Channel %1: ] Block %2: %]Island is outside the pocket
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check programming of the island/pocket contour
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61950
%[[Channel %1: ] Block %2: %]No residual material available
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61951
%[[Channel %1: ] Block %2: %]Cutter radius for residual material too large
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Use cutter with smaller radius
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
501