Explanation:
Error in SDB for configuring PROFIBUS/PROFINET.
Causes of the error:
- 01 = SDB does not exist in source.
- 02 = SDB from source is too large.
- 03 = SDB from source cannot be activated.
- 04 = Source is empty.
- 05 = Source is not present.
SDB source:
- 99 = Passive file system: _N_SDB_DIR
- 100 = CF card: /siemens/sinumerik/sdb/...
- 101 = CF card: /addon/sinumerik/sdb/...
- 102 = CF card: /oem/sinumerik/sdb/...
- 103 = CF card: /user/sinumerik/sdb/...
Reaction: PROFIBUS/PROFINET is inactive or working with the default SDB.
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check the setting of MD 11240 $MN_PROFIBUS_SDB_NUMBER.
- If source = 100: Check directory _N_SDB_DIR in the passive file system.
- If source = 103-106: Check directories on CF card
Programm
continuation:
Switch control OFF - ON.
380022
PROFIBUS/PROFINET: Configuration of DP master bus %1 has been changed
Parameters:
%1 = Number of the affected bus
Explanation:
The PROFIBUS configuration on the DP master was changed during operation, e.g. by downloading a new hardware
configuration via STEP 7. As the cycle data may also have changed, operation cannot be continued, and a warm start is
required.
If the master functionality is within the PLC (as on the 840Di), the PLC will have been stopped for the download, and alarm
2000 (PLC sign-of-life) output.
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system
manufacturer.
Programm
continuation:
Switch control OFF - ON.
380040
PROFIBUS/PROFINET: Bus %3, configuration error %1, parameter %2
Parameters:
%1 = Cause of the error
%2 = Parameter
%3 = Number of the affected bus
SINUMERIK 808D ADVANCED alarms
5.4 Drive alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
515