Programm
continuation:
Switch control OFF - ON.
400009
Computing time overrun at PLC level: %2 network %1
Explanation:
%1 : Network number
%2 : Module type
Check user program of the corresponding network displayed.
Reaction:
PLC Stop
Remedy:
Change user program
Programm
continuation:
Switch control OFF - ON.
400010
Arithmetic error in user program: Type %2 network %1
Explanation:
Check user program in the specified network.
%1 Network number, module ID
%2 = 1: Division by zero using fixed-point arithmetic
2: Floating-point arithmetic
Reaction:
PLC Stop
Remedy:
Change user program.
Programm
continuation:
Switch control OFF - ON.
400011
Maximum number of subroutine levels exceeded: %2 network %1
Explanation:
%1 Network number
%2 Module ID
Check user program in the specified network.
Reaction:
PLC Stop
Remedy:
Change user program.
Programm
continuation:
Switch control OFF - ON.
400012
Error affecting indirect addressing: %2, network %1
Explanation:
%1 Network number
%2 Module ID
Check user program in the specified network.
Reaction:
PLC Stop
Remedy:
Change user program.
Programm
continuation:
Switch control OFF - ON.
400013
PLC user program is incorrect
Explanation:
The PLC user program in the control is incorrect or is not available.
Reaction:
PLC Stop
Remedy:
Reload PLC user program.
Programm
continuation:
Switch control OFF - ON.
SINUMERIK 808D ADVANCED alarms
5.5 PLC alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
523