4012
Invalid identifier used in machine data %1[%2]
Parameters:
%1 = String: MD identifier
%2 = Index: MD array
Explanation:
The selected identifier is invalid. Valid identifiers are:
- AX1 - AXn: Machine axis identifiers
- N1AX1 - NnAXm: Link axis identifiers (NCU + machine axis), only for 'NCU-Link' expansion level!
- C1S1 - CnSm: Container axis identifiers (con container location), only for 'Axis container' expansion level!
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use the correct identifier.
Programm
continuation:
Switch control OFF - ON.
4020
Identifier %1 used several times in machine data %2
Parameters:
%1 = String: Name of identifier
%2 = String: MD identifier
Explanation:
When determining a name in the NCK tables (arrays) for: machine axes, Euler angles, direction vectors, normal vectors,
interpolation parameters and intermediate point coordinates, an identifier has been used that already exists in the control.
When determining a name in the NC tables (arrays) for machine axes, an identifier has been used that already exists in
the control.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Select for the identifier to be entered a character string that
is not yet used in the system (max. 32 characters).
Programm
continuation:
Restart part program. Clear alarm with the RESET key in all channels of this mode group. Restart part program.
4021
[Channel %1: ] Identifier %2 used several times in machine data %3
Parameters:
%1 = Channel number
%2 = String: Name of identifier
%3 = String: MD identifier
Explanation:
To determine the name in the channel-specific tables for geometry axes and channel axes an identifier already existing
in the control has been used.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Select for the identifier to be entered a character string that
is not yet used in the system (max. 32 characters).
Programm
continuation:
Switch control OFF - ON.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
54
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2